Mfg Part Number: EH3-B100-F2 | Alternate P/N: EH3B100F2 | NSN : 5925-01-078-2374 |
NIIN : 010782374 | CAGE Code : 66842 | Manufacturer: Siemens Energy And Automation Inc |
Item Name : Circuit Breaker | FSC : 5925 Circuit Breakers |
ASAP Integrated Distribution is a purchasing platform owned and operated by ASAP Semiconductor, and we are your sourcing solution for EH3-B100-F2 Circuit Breaker NSN parts with NSN 5925-01-078-2374. This EH3-B100-F2 NSN product is manufactured by Siemens Energy And Automation Inc. If you are interested in this item and would like to kickstart the procurement process with a quote for your comparisons, complete and submit the form provided below at your earliest convenience. Once we receive a form, a dedicated account manager will rapidly formulate a customized solution and personally reach out to you within 15 minutes or less.
To ensure that customers only purchase the exact parts that they require, we list items with all applicable information. For example, NSN 5925-01-078-2374 was specifically produced under the CAGE Code 66842, denoting the specific Siemens Energy And Automation Inc facility that its production traces back to. Additionally, we conduct extensive document verification, ensuring that our offerings are traceable, up to required standards, and more. With our steadfast dedication to quality control and compliance, we operate with AS9120B, ISO 9001:2015, and FAA AC 00-56B accreditation. Kickstart the procurement process for the NSN parts you need with an RFQ, and we will do the rest for you!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-078-2374 Item Description: Circuitbreaker | 5925 | 010782374 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Eh3-B100-F2 | 5 | 1 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.984 INCHES MINIMUM AND 6.016 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.484 INCHES MINIMUM AND 4.516 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.109 INCHES MINIMUM AND 5.141 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.577 INCHES MINIMUM AND 4.609 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.484 INCHES MINIMUM AND 1.516 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.202 INCHES MINIMUM AND 0.234 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.983 INCHES MINIMUM AND 4.015 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 15000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT EACH POLE |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
CRTK | SWITCH TERMINAL TYPE | WIRE LEAD |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL AND C0NTACT SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT, FEMALE |
ZZZK | SPECIFICATION/STANDARD DATA | 01714-G376972-1 MANUFACTURERS SOURCE CONTROL |
![]() |